Fluid-liquid extraction


Service : 230 V / 50 Hz / Single phase: 1 kW.
Evacuation of solvent vapors
Dimensions : 1,7 m x 0,85 m x 3,16 m
Poids : 120kg

Imprimer/télécharger la fiche produit
DEMANDER UN DEVIS POUR CETTE MACHINE

Principle and operation

Liquid-liquid extraction is used to transfer a solute (dissolved in a diluent and forming the solution) into a solvent with which it has more affinity; the diluent and the solvent are immiscible.
The light phase is introduced at the bottom of the column and then goes back to the upper decanter of the column. The heavy phase introduced at the top of the column goes down to the settling zone located at the bottom. A stirring assembly (consisting of a succession of turbines and settling trays distributed along the column) allows a mixture of the two phases circulating against the current and causes the transfer of the solute to be extracted in the solvent. Decanters are used for the separation of immiscible phases; the solute enriched extract phase and the solute depleted raffinate phase are continuously withdrawn from these settlers.

Objectifs Pédagogiques :
  • Influence of solution and solvent flow rates
  • Influence of agitation.
  • Material balance.
  • Number of theoretical plates (McCABE and THIELE, ternary diagrams).
  • Number of transfer units.
  • Coefficients of exchange of matter.
Description technique :

Equipment

  • Two cans of solution storage and polyethylene feed solvent.
  • Dosing pump feeding the solution,
  • Solvent supply metering pump,
  • Lower borosilicate glass settling tank with light phase introduction, heavy phase output and sampling valve.
  • Upper borosilicate glass settling tank with heavy phase introduction, light phase outflow by overflow and sampling valve.
  • Borosilicate glass column,
  • 316L stainless steel turbine stirring unit driven by a variable speed electric motor.
  • Four guiding and sampling trays in 316L stainless steel.
  • Recipe of borosilicate glass extract phase
  • Recipe for the borosilicate glass raffinate phase
  • 316L stainless steel connection pipes.
  • Support frame in 304L stainless steel tubes and aluminum nuts.


Instrumentation

  • Control and control cabinet, IP55, equipped with emergency stop, operating buttons and the following interfaces:
  • Variator of the stirring speed.
  • Digital indicator of stirring speed.
Options :
Option: Digital temperature indicator of two probes type Pt100 & # 937.
DEMANDER UN DEVIS POUR CETTE MACHINE

Autres machines associées à la catégorie Génie Chimique
Mélangeur granulateur secheur
MP411
En savoir plus
Cristallisation cascade de laboratoire
MP1002
En savoir plus
Évaporation - cristallisation discontinue
MP1003
En savoir plus
Évaporation - cristallisation continue
MP1004
En savoir plus
Distillation continue
MP1010
En savoir plus
Distillation continue
MP1010CR
En savoir plus
Distillation continue supervisée
MP1011
En savoir plus
Distillation continue supervisée
MP1011CR
En savoir plus
Distillation continue azeotropique
MP1012
En savoir plus
Distillation discontinue
MP1020
En savoir plus
Distillation discontinue
MP1020CR
En savoir plus
Distillation flash
MP1025
En savoir plus
Ébulliometrie dynamique atmospherique
MP1026
En savoir plus
Extraction liquide-liquide agitée
MP1030
En savoir plus
Extraction liquide-liquide agitee supervisee
SP1030
En savoir plus
Extraction liquide-liquide agitée
MP1030CR
En savoir plus
Extraction liquide-liquide pulsee
MP1031
En savoir plus
Extraction solide/liquide discontinue (soxhlet) et distillation discontinue
MP1035
En savoir plus
Extraction solide/liquide discontinue (soxhlet)
MP1036
En savoir plus
Absorption / desorption
MP1040
En savoir plus
Absorption / desorption
MP1040CR
En savoir plus
Évaporateur à film ascendant
MP1050
En savoir plus
Évaporateur à film ascendant double effet
MP1052
En savoir plus
Réacteur agité 10 litres
MP1070
En savoir plus
Réacteur agité 10 litres polyvalent
MP1071
En savoir plus
Réacteur de laboratoire
MP1073
En savoir plus
Réacteur de laboratoire
MP1073
En savoir plus
Unité de synthese polyvalente 25 litres
MP1074
En savoir plus
Unité de synthèse polyvalente 50 litres
MP1075
En savoir plus
Réacteurs agités - piston
MP1076
En savoir plus
Pilote de traitement des eaux usées
MP42
En savoir plus
Mélangeur, décanteur, extraction liquide-liquide
MP1032
En savoir plus