Votre devis (0 machine)
Accueil > Agroalimentaire, Pharmaceutique et Biotechnologies > Génie Pharmaceutique et Biotechnologies > MP314S

Laboratory atomization


Service : 400 V / 50 Hz / Three phase: 7 kW
Compressed air 6 bar: 5Nm3 / h
Evacuation of fines outside the laboratory.
Dimensions : 1,95 m x 0,7 m x 2,6 m
Poids : 150kg

Imprimer/télécharger la fiche produit
DEMANDER UN DEVIS POUR CETTE MACHINE

Description :
  • Industrial instrumentation
  • Borosilicate glass construction (304 stainless steel optional).
  • Rigid process piping

     

The solution of a product in a solvent (water) is dehydrated to obtain the product as a powdery solid.
The solution is injected through an atomization nozzle which generates a mist formed of very small droplets.
A very hot air stream makes it possible to evaporate the solvent forming the droplets and to entrain the solid in a cyclone.
This allows the solid particles formed to separate from the drying air which escapes outside the pilot.
The solid is recovered at the foot of the cyclone in a suitable reserve.

 

Experimental parameters studies following :
 

  • Study of the atomization of a solution.
  •  Influence of the heating temperature of the drying air.
  •  Influence of drying air flow.
  •  Influence of the atomizing air flow.
  •  Influence of the feed rate of the product.
  •  Thermal balances.
  •  Material balance.
Spécifications techniques :
  • Food bottle.
  • Peristaltic pump supplying the variable flow solution.
  • Centrifugal air dryer with adjustable flow rate steel.
  • Stainless steel hot air supply duct with variable heating resistor e 6000 W.
  • Borosilicate glass atomization chamber (stainless steel optional) with borosilicate glass receiving jar.
  • Atomising nozzle with air supply and timed unclogging system with cyclic air supply.
  • Air separation cyclone - borosilicate glass solid (stainless steel optional) with borosilicate glass solid receiving jar.
  • Evacuation of fines with cleanable filter.
  • Supply air flow measurement by hot wire probe.
  • Measurement and adjustment of atomizing air supply flow (nozzle supply) by float flowmeter and integrated control valve.
  • Solenoid valve for cleaning the spray nozzle.
  • Safety thermostat of the air heating resistor.
  • Relative humidity measurement by two hygrometric probes at the entrance and exit of drying air with multi-channel digital indicator.
  • Control and control cabinet, IP55, equipped with emergency stop, operating buttons and the following interfaces:
  • - Digital drying airflow indicator with active low alarm.
  • - Digital indicator of the temperature of the atomization chamber by probe type Pt100 Ω.
  • - Digital regulator of drying air temperature.
  • - Electronic speed controller of the drying air fan.
  • - Electronic speed controller of the feed pump.
  • - Electronic timer for unclogging the atomization nozzle
DEMANDER UN DEVIS POUR CETTE MACHINE

Autres machines associées à la catégorie Génie Pharmaceutique et Biotechnologies
Doseuse volumétrique
MP804
En savoir plus
Atomisation de laboratoire
MP314S
En savoir plus
Pilote d'ultrafiltration
MP350B
En savoir plus
Tamis vibrant en continu
MP412
En savoir plus
Comprimeuse alternative
MP413
En savoir plus
Malaxeur à crèmes
MP430
En savoir plus
Ultrafiltre de laboratoire
MP351
En savoir plus
Machine à doser les liquides ou formes stériles
MP805
En savoir plus
Chromatographie par échange d'ions
MP300
En savoir plus
Mélangeur-granulateur-sécheur
MP411
En savoir plus