Skip to content. | Skip to navigation

Sections
You are here: Home / Process Engineering / Process Engineering / Environmental Engineering / DEFERRISATION – DECHLORATION – DESINFECTION PILOT MP33

DEFERRISATION – DECHLORATION – DESINFECTION PILOT MP33

This pilot can treat water by physical way and chemical or biological way with disinfections by chlorine.

MP33

Teaching objectives

- To understand a de-ironing process with flocculation and/or oxidation according to the form of the iron present in water.
- To understand the use of the active charcoal in order to dechlorinate water.
We will be able to treat the products coming out of the sand filter
- In option, the radiation U.V treatment device will be able to be used either only, either after the two columns, the sand filter alone or the biologic filter alone. This treatment act without addition of reagent and is interesting to know

 

Technical specifications

- a physical filtration column which can contain several types of granular materials (anthracite, calcareous, quartz),
- a chemical filtration column ontaining activated charcoal for dechlorination or activated charcoal for biologic reaction,
- a centrifugal, auto-start feeding pump, a flowmeter and a diaphragm valve
- three feeding and reception filtrate tanks (one is provided with a circulator),
- a measuring pump for the measurement of the oxidising agent,
- a measuring pump for the measurement of the flocculant agent,
- two manometers to visualize the clogging of the filters,
- a control panel for the pumps and their motor safety devices, the chlorine transmitter-regulator
- stainless steel frame with aluminium nuts and PVC panel
- Technical manual in English

Option : Treatment by UV including :
- A sterilizer UVD 13.
- Integration of the UV control device in the control cabinet

 

Dimensions

2 000 x 800 x 2100 mm

 

Essential requirements

Power supply : 220 V / single phase / 50 Hz

 

MP33 diagram - click to enlarge :

MP33 SA

 

MP33

 

MP33