FLOW- LEVEL - PRESSURE - TEMPERATURE CONTROL BENCH MP111M

MP111M

- Control of water level in loop
- Control of water flow by winnowing
- Control of water pressure by winnowing
- Control of water temperature, (piloting resistive charges per static power unit)
- Control of water temperature with cascade on the flow

Teaching objectives

- Study of the closed loop system :
- stability conditions
- response to a level instruction
- influence of the parameters of control and the algorithm setting (TOR, P, PI, or PID) on the results
- Study of an open loop system
-Study of the characteristic curves of the system
- Study of a cascade control system

 

Technical specifications

- a supply tank of 50 liters out of PVC, with taping and overflow
- a Altuglass column high 1200 mm , diam. 200 mm with overflow and drain tap
- a centrifugal pump, 380 V three phases
- a master regulator with universal input, output 4-20 mA and a slave regulator, regulation algorithm P, PI, PID, PD + MR. function auto/manual – auto-adaptative with double display measure/instruction
- proportional pneumatic valve, with positioning
- I/P Converter
- Pressure control by pressure transmitter (output 4-20 mA)
- Electronic flowmeter (output 4-20 mA)
- 4 rotary flowmeters with tap
- Level measurement by pressure transmitter (4-20 mA) placed at the bottom of an Altuglass water column with overflow and drain valve.
- immersion heater with thermostat
- 2 temperature probes Pt 100 ohms with transmitter 4/20 mA
- an electric cabinet including :
the regulators,
the protection of the pump and its command
Wiring of the closed loop thanks safe jacks and wires
Mounted on a stainless steel frame with aluminium nut.

5 Process are possible :

1 - level control
Actuator : pneumatic valve
Sensor : pressure transmitter
Disruption : leak on the pipe , leak under the column.

2 – Flow control
Actuator : pneumatic valve
Sensor : Electronic flowmeter
Disruption : leak on the pipe

3 – Pressure control
Actuator : pneumatic valve
Sensor : pressure transmitter
Disruption : leak on the pipe

4 - Temperature control
Actuator : immersion heater
Sensor : temperature probe
Disruption : by provision of cold water

5 - regulation cascades of temperature/débit
Actuator : pneumatic valve
Sensor : temperature probe at the ouput of the heater and electronic flowmeter
Disruption : leak on the pipe, variation of the heater’s power

 

Dimensions and weight

- 1500 x 800 x 2100 mm

- Weight:  about 150 kg

 

Essential requirements

- Electric power supply: 7 kW 380 V triphase.
- Compressed air: 6Nl/h, 6 bars,

 

 

Services nécessaires

Consommation 0,37 kW – 220 V monophasé.
Documentation pédagogique et technique.

 

MP111M